NEWS

Daily Maintenance Of Air Blower

Date Issued:2022-02-12
Daily Maintenance Of Air Blower

1.Maintenance of the impeller
The impeller is the rotating part of the fan, and its function is to transport the gas through the fan to the gas outlet. It consists of a rear disc, a straight front disc with an inlet ring and blades.
The blade is composed of arc-plate blades with a larger radius of curvature. During the initial stage of impeller operation and all periodic inspections, whenever possible,
It is necessary to check whether the impeller is reliably fixed on the shaft shoulder, and whether the impeller has defects such as cracks, wear, and dust accumulation. Keep the impeller clean, and regularly use a wire brush to remove the dust and rust on it. Because as the running time increases,
Because these dusts cannot be evenly attached to the impeller, the balance of the impeller is destroyed, which causes the rotor to fluctuate.

2.Maintenance of casing and intake chamber
Except for regular inspection of the casing and the interior of the air intake chamber for serious wear and tear and removal of serious dust accumulation, no other maintenance is required for these parts.
Regularly check whether all the fastening bolts are tight, and press the butterfly spring on the foot to the installation height specified in the drawing.

3.Maintenance of main shaft and coupling
The main shaft should be kept clean, and the shaft shoulder should be scraped off every year. Special attention should be paid to the position where the main shaft passes through the shaft end seal of the side plate of the intake chamber.
Corrosion is likely to occur at these locations due to air condensation from small leaks.
If the fan runs in an unbalanced state for a period of time, the straightness of the main shaft should be checked as much as possible. Couplings should be kept clean and regularly checked for tightness.

4.Maintenance of bearings
Always check the lubrication and oil supply of the bearing. If there is oil leakage in the box, the bolts of the end cover can be tightened a little. If this does not work, a new seal needs to be replaced.
When the lubricating oil of the bearing is used normally, it should be replaced at least once in half a year. When it is used for the first time, the oil should be inspected at least once in half a year.